Please wait for your ready for pick-up email before heading to your local store.  Learn More

HomeLine Single Pole 15 Amp Combination Arc Fault Plug-On Circuit Breaker

Model # CHOM115PCAFI|Store SKU # 1001002722

Overview

Model # CHOM115PCAFI Store SKU # 1001002722

Beginning in 2015, the Canadian Electrical code will require the use of Combination Arc Fault Circuit Interrupters (CAFCIs) in each branch circuit in the home supplying 125V receptacles rated 20A or less (except in the kitchen/bathrooms and sump pump). The CAFCI breaker effectively stops the flow of current before an electrical fire from dangerous arcing can start. Typical causes of dangerous arc faults in a residence are: cord insulation damage from furniture, drywall screw piercing insulation, punctured cable by nail or staple. A standard feature in all HomeLine CAFCI circuit breakers is the TIME SAVER diagnostics test that assists in identifying the type of fault that last occurred in a circuit. It saves money by reducing troubleshooting time, simple to use and requires no tools.

  1. Detects unintended arc faults, overloads and short circuits
  1. No neutral pigtail, direct connection to loadcentre neutral bar
  1. Plug-on (pigtail less) CAFCI version helps minimize installation time by reducing the number of runs and wires
  1. Built in TIME SAVER diagnostics feature
  1. White push to test button
  1. Compatible only with Canadian HomeLine plug-on neutral loadcentres

Specifications

Dimensions

Assembled Depth (in inches)
3
Assembled Height (in inches)
4.75
Assembled Weight (in lbs)
0.55
Assembled Width (in inches)
1
Packaged Depth (in inches)
3
Packaged Height (in inches)
4.75
Packaged Weight (In lbs)
0.546
Packaged Width (in inches)
1

Details

Certified
Yes
Country of Origin
MX-Mexico

Warranty / Certifications

Limited lifetime warranty
Single Pole 15 Amp Combination Arc Fault Plug-On Circuit BreakerHomeLine Single Pole 15 Amp Combination Arc Fault Plug-On Circuit BreakerBeginning in 2015, the Canadian Electrical code will require the use of Combination Arc Fault Circuit Interrupters (CAFCIs) in each branch circuit in the home supplying 125V receptacles rated 20A or less (except in the kitchen/bathrooms and sump pump). The CAFCI breaker effectively stops the flow of current before an electrical fire from dangerous arcing can start. Typical causes of dangerous arc faults in a residence are: cord insulation damage from furniture, drywall screw piercing insulation, punctured cable by nail or staple. A standard feature in all HomeLine CAFCI circuit breakers is the TIME SAVER diagnostics test that assists in identifying the type of fault that last occurred in a circuit. It saves money by reducing troubleshooting time, simple to use and requires no tools.
HomeLine
1001002722
Single Pole 15 Amp Combination Arc Fault Plug-On Circuit Breaker is rated 5.0 out of 5 by 2.
  • y_2021, m_1, d_23, h_17
  • bvseo_bulk, prod_bvrr, vn_bulk_3.0.13
  • cp_1, bvpage1
  • co_hasreviews, tv_1, tr_1
  • loc_en_CA, sid_1001002722, prod, sort_[SortEntry(order=SUBMISSION_TIME, direction=DESCENDING)]
  • clientName_homedepot-canada
  • bvseo_sdk, java_sdk, bvseo-4.0.0
  • CLOUD, getAggregateRating, 77ms
  • REVIEWS, PRODUCT
Rated 5 out of 5 by from Worked as expected I've used the arc fault breakers with the pigtail before and thought I'd try this one. Went in just as easy as a regular breaker. Very happy with it.
Date published: 2017-11-30
  • y_2021, m_1, d_23, h_17
  • bvseo_bulk, prod_bvrr, vn_bulk_3.0.13
  • cp_1, bvpage1
  • co_hasreviews, tv_1, tr_1
  • loc_en_CA, sid_1001002722, prod, sort_[SortEntry(order=SUBMISSION_TIME, direction=DESCENDING)]
  • clientName_homedepot-canada
  • bvseo_sdk, java_sdk, bvseo-4.0.0
  • CLOUD, getReviews, 25ms
  • REVIEWS, PRODUCT
  • bvseo_sdk, java_sdk, bvseo-4.0.0
  • CLOUD, getContent, 89ms
  • QUESTIONS, PRODUCT
  • bvseo-msg: The resource to the URL or file is currently unavailable.;