    Model # CT410A1001 Store SKU # 1000429052

    The easy-to-install Honeywell Manual 2-Wire Electric Baseboard Heat Thermostat works on 2-wire electric heat applications (electric baseboard heaters or line volt) and allows for simple, worry-free operation. It has a simple dial-type mechanical control for simple, worry-free operation.

    1. Low volt thermostat for central heating systems including furnaces, boilers, air conditioning, and heat pumps
    1. Easy to install
    1. Bimetal temperature sensor
    1. 2-wire application
    1. Mercury-free
    1. Easy to install

    Specifications

    Dimensions

    Assembled Depth (in inches)
    2
    Assembled Height (in inches)
    4.5
    Assembled Weight (in lbs)
    0.35
    Assembled Width (in inches)
    2.75
    Packaged Depth (in inches)
    2.5
    Packaged Height (in inches)
    7.9375
    Packaged Weight (In lbs)
    0.7000000000000001
    Packaged Width (in inches)
    6.375

    Details

    Battery Operated
    Yes
    Built-in Wifi
    Yes
    Certified
    Yes
    Colour Family
    White, White
    Country of Origin
    MX-Mexico
    Line Voltage Thermostat
    Yes, Yes
    Touch Screen
    Yes

    Warranty / Certifications

    1 Year Limited 1-800-468-1502
    Manual 2-Wire Electric Baseboard Heat ThermostatPhoto of productThe easy-to-install Honeywell Manual 2-Wire Electric Baseboard Heat Thermostat works on 2-wire electric heat applications (electric baseboard heaters or line volt) and allows for simple, worry-free operation. It has a simple dial-type mechanical control for simple, worry-free operation.
    Honeywell
    1000429052
    Manual 2-Wire Electric Baseboard Heat Thermostat is rated 4.0 out of 5 by 7.
    • y_2019, m_9, d_13, h_8
    • bvseo_bulk, prod_bvrr, vn_bulk_2.0.13
    • cp_1, bvpage1
    • co_hasreviews, tv_2, tr_5
    • loc_en_CA, sid_1000429052, prod, sort_[SortEntry(order=SUBMISSION_TIME, direction=DESCENDING)]
    • clientName_homedepot-canada
    • bvseo_sdk, java_sdk, bvseo-4.0.0
    • CLOUD, getAggregateRating, 81ms
    • REVIEWS, PRODUCT
    Rated 5 out of 5 by from Excellent quality. Great price. I bought this thermostat for my baseboard heater. Excellent and great price!
    Date published: 2019-01-28
    Rated 2 out of 5 by from Works well but packaging is misleading I purchased this for a 240 fan forced heater. No problems thus far as the packaging says 120/240v on it. BUT, I suspect that for cost-cutting reasons, the marketing geniuses at Honeywell decided to use the same packaging for the ct410a and ct410b. The former has 1 pole and the other has 2. Guess where it says that on the package? Absolutely nowhere. And, they block the rear of the packaging with useless foam, so you can't even check before opening the package. Not putting yourself in the customer's shoes seems to be more and more common, as evidenced by the extremely helpful instructions. I already know how to install one, but for someone who is more of a novice? Next time, I'll do more research on my own before getting to the store. But I will try to find a different company's products, just because this type of thing really irritates me.
    Date published: 2015-01-05
    Rated 1 out of 5 by from Specs This is not a "close on rise" switch thermostat. despite the fact it says it can do heat and cooling.
    Date published: 2011-10-15
    Rated 5 out of 5 by from Honeywell temperature controlled stray cat shelter Thanks to this inexpensive efficient Honeywell thermostat and 100 watt light bulb, Sneaker's (stray cat) outdoor shelter remains at a constant 15 degrees C during the cold winter months. Plenty of food and water but misses human contact. Ongoing project is to find him a loving home.
    Date published: 2009-01-08
    Rated 5 out of 5 by from bought 2 last time. working well. I bought 2 last year. They are working well. I am going to go buy another 5 if I can go through the online process.
    Date published: 2008-12-15
    • y_2019, m_9, d_13, h_8
    • bvseo_bulk, prod_bvrr, vn_bulk_2.0.13
    • cp_1, bvpage1
    • co_hasreviews, tv_2, tr_5
    • loc_en_CA, sid_1000429052, prod, sort_[SortEntry(order=SUBMISSION_TIME, direction=DESCENDING)]
    • clientName_homedepot-canada
    • bvseo_sdk, java_sdk, bvseo-4.0.0
    • CLOUD, getReviews, 28ms
    • REVIEWS, PRODUCT

    I got 3 - CT410A1001 thermostats to replace old programmable ones. I was told at the store that they worked with line voltage AND low voltage systems. I can't get the new one to work. I called an electrician he said no way. Who is right?

    Asked by: perplexed
    Hello perplexed! The Honeywell Manual 2-Wire Electric Baseboard Heat Thermostat will only work with line voltage control of a radiant cable, electric baseboard and resistive rated fan forced heaters. This thermostat will not work with a low voltage heating or cooling system. I do apologize for any inconvenience this may cause you. Thank you.
    Answered by: Honeywell Support
    Date published: 2018-11-14

    I have a gas fireplace fan attached to a common single pole light switch. Could I use this to control the fan?

    Asked by: Anonymous
    Hello! The Honeywell Electric Baseboard Thermostat is compatible with most 120/240 volt heating systems. Compatible system types include radiant, cable, electric baseboard and resistive rated fan forced heaters. For further assistance in determining the compatibility of your system with this thermostat, please feel free to contact Honeywell Technical Support at (800) 468-1502. Thank you.
    Answered by: Honeywell Support
    Date published: 2017-02-02

    Four pole thermostat

    Ordered and installed the four wire version of this thermostat as we have two baseboard heaters on one control. Now no matter where you set this one one the dial it will cut out at 60 and not go any higher. replaced the old one because it would not cut out anymore.
    Asked by: Anonymous
    Hello. This sounds like there may be some sort of limit set on the thermostat. For assistance with how to control your Honeywell Electric Baseboard Thermostat please feel free to contact Honeywell Technical Support at (800) 468-1502. Thank you.
    Answered by: Honeywell Support
    Date published: 2017-01-25

    Off switch?

    Does this thermostat turn off or is it like the old units that will always go on no matter how far you turn it counter clockwise.
    Asked by: Anonymous
    Hello, the Honeywell Electric Baseboard Thermostat does not have an option to turn the system off. This is a line voltage thermostat that is designed to work with electric heating systems such as a baseboard heater, a convector or a fan-forced heater. For further assistance in determining compatibility of your HVAC system with this thermostat, please feel free to contact Honeywell Technical Support at (800) 468-1502. Thank you.
    Answered by: Honeywell Support
    Date published: 2017-01-25

    What are the switches rated for, I'm assuming 120 Vac 15 amp on each pole ?

    Asked by: Anonymous
    These are for 120v 20A. The ct410b are 240v 20a2p.
    Answered by: mrphandy
    Date published: 2016-11-11

    can you use this on a gas furnace?

    Asked by: Anonymous
    No, this is designed for line-voltage baseboard heaters.
    Answered by: EngGuy
    Date published: 2015-12-30

    Thermostat turns on too early

    My thermostat turns on (a heater starts to heat up) too eraly. To maintain the rrom temperature on 18C I have to set the thermostat to just 10C. What is wrong? Thanks for help.
    Asked by: Anonymous
    Hello, I would suggest calling technical support at 1 800 468 1502 to ensure that the thermostat is running properly.
    Answered by: hwman
    Date published: 2018-09-27

    My base board heaters have power so why won't the thermostat work?

    Asked by: Anonymous
    Hello, It sounds like there maybe an issue with the thermostat or the connection. I would recommend calling tech support at 1-800-468-1502, as they could better answer your question.
    Answered by: hwman
    Date published: 2013-10-23
    • y_2019, m_9, d_13, h_8CST
    • bvseo_bulk, prod_bvqa, vn_bulk_2.0.13
    • cp_1, bvpage1
    • co_hasquestionsanswers, tq_10
    • loc_en_CA, sid_1000429052, prod, sort_[SortEntry(order=LAST_APPROVED_ANSWER_SUBMISSION_TIME, direction=DESCENDING)]
    • clientName_homedepot-canada
    • bvseo_sdk, java_sdk, bvseo-4.0.0
    • CLOUD, getContent, 56ms
    • QUESTIONS, PRODUCT
    <?xml version="1.0" encoding="utf-8"?>