    Push'N'Connect Wall Hydrant with Vacuum Breaker 12 Inch

    Model # 1375012|Store SKU # 1000723719

    Overview

    Model # 1375012 Store SKU # 1000723719

    Push on connection, no special tools required. Works on Copper, Pex and CPVC pipe. Nailing flange to help ensure hydrant drains properly. Angle configuration for easy hose attachment.

    1. Push On Connection
    1. No Special Tools Required
    1. Works on Copper, Pex & CPVC pipe

    Specifications

    Dimensions

    Assembled Depth (in inches)
    12
    Assembled Height (in inches)
    1.50
    Assembled Weight (in lbs)
    1.28
    Assembled Width (in inches)
    1.50
    Packaged Depth (in inches)
    18
    Packaged Height (in inches)
    5
    Packaged Weight (In lbs)
    6.4
    Packaged Width (in inches)
    4.85

    Details

    Certified
    Yes
    Country of Origin
    CN-China

    Warranty / Certifications

    CALL 1-800-361-3773
    Wall Hydrant with Vacuum Breaker 12 InchPush'N'Connect Wall Hydrant with Vacuum Breaker 12 InchPush on connection, no special tools required. Works on Copper, Pex and CPVC pipe. Nailing flange to help ensure hydrant drains properly. Angle configuration for easy hose attachment.
    Push'N'Connect
    1000723719
    Wall Hydrant with Vacuum Breaker 12 Inch is rated 2.8 out of 5 by 4.
    • y_2020, m_9, d_17, h_16
    • bvseo_bulk, prod_bvrr, vn_bulk_3.0.12
    • cp_1, bvpage1
    • co_hasreviews, tv_0, tr_4
    • loc_en_CA, sid_1000723719, prod, sort_[SortEntry(order=SUBMISSION_TIME, direction=DESCENDING)]
    • clientName_homedepot-canada
    • bvseo_sdk, java_sdk, bvseo-4.0.0
    • CLOUD, getAggregateRating, 86ms
    • REVIEWS, PRODUCT
    Rated 1 out of 5 by from terrible product purchased and installed for about a year no issues vaccume breaker float has broken causing major leaks and loss of pressure And HD does not carry replacement parts! So the option is to tear out the whole assembly reconnect pex etc. If you carry a plumbing product provide repair parts!!!!! They only carry the screw caps
    Date published: 2018-11-06
    Rated 4 out of 5 by from Easy setup I replace one that the vacuum breaker was leaking with this one. Works great, easy installation. I gave 4 star because it's only been a month. Time will tell if it deserves the 5th star.
    Date published: 2018-08-13
    Rated 1 out of 5 by from Not recommended I installed this hydrant very carefully, but unfortunately it leaked at the push-in connection and water spewed out of the vacuum breaker. On disassembly, I found a damaged o-ring in the slip connection, despite chamfering and smoothing the end of the copper pipe. Not sure why the breaker leaks so badly, maybe it is missing a part. Product comes with no instructions re pipe prep, insertion depth, breaker function, etc.
    Date published: 2018-07-23
    Rated 5 out of 5 by from Outstanding product and easy installation I've installed dozens of these frost free hose bibs over the years. This item is without a doubt the easiest to install. Bulletproof design, solid construction, versatile connection, great reliability...you couldn't ask for more! I've installed two on the exterior of my house in Guelph. Within two months, a dozen neighbours wanted their fixtures upgraded too. Just verify your slope. Installation takes less than 15 minutes.
    Date published: 2018-01-08
    • y_2020, m_9, d_17, h_16
    • bvseo_bulk, prod_bvrr, vn_bulk_3.0.12
    • cp_1, bvpage1
    • co_hasreviews, tv_0, tr_4
    • loc_en_CA, sid_1000723719, prod, sort_[SortEntry(order=SUBMISSION_TIME, direction=DESCENDING)]
    • clientName_homedepot-canada
    • bvseo_sdk, java_sdk, bvseo-4.0.0
    • CLOUD, getReviews, 24ms
    • REVIEWS, PRODUCT

    Installed this after our last vaccum breaker broke. The water pressure is less than half of what it used to be, without the valve it is fine, pipe is clean. With the valve no pressure. Could the mechanism be defective?

    Asked by: Ashley
    Thanks for your inquiry. There are a few different things that might have caused this problem, it cannot be diagnosed definitely online. May we ask you to contact us toll free at 1-800-361-3773 and ask for Retail Sales Coordinator so we can discuss in further details. Please reference "Wall Hydrant". Thank you
    Answered by: Waterline Products
    Date published: 2019-06-14

    I just replaced an old wall hydrant with this one and now the water pressure is about half what is was before. Any suggestions?

    Asked by: joe76
    The issue could be stemming from which type of pipe you are using copper or plastic pex pipe? If your pipe is copper you will need to remove the the white insert tip at the end as this will reduce water flow on a copper pipe. If your pipe is a pex plastic pipe you will need to keep the white insert tip on which will be inserted into the plastic pipe as a stiffener to ensure the pipe stays open completely for full water flow. Hope you find this information helpful. Thanks for the question.
    Answered by: Waterline Products
    Date published: 2019-05-19

    wall hydrant with vacuum breaker leaking from top cap ,can this be fixed or does it need to be replaced

    Asked by: wayne
    The vacuum breaker can be removed and replaced. However, we find that many people find it difficult to install a new vacuum breaker correctly, or they break the new one during installation - so those who are uncertain should replace the hydrant. As well, to prevent one potential cause of this problem, please ensure that the wall hydrant is installed at the correct angle, using the plastic shim that was provided with it.
    Answered by: The Home Depot Canada
    Date published: 2019-05-19
    • y_2020, m_9, d_18, h_17CST
    • bvseo_bulk, prod_bvqa, vn_bulk_3.0.12
    • cp_1, bvpage1
    • co_hasquestionsanswers, tq_3
    • loc_en_CA, sid_1000723719, prod, sort_[SortEntry(order=LAST_APPROVED_ANSWER_SUBMISSION_TIME, direction=DESCENDING)]
    • clientName_homedepot-canada
    • bvseo_sdk, java_sdk, bvseo-4.0.0
    • CLOUD, getContent, 104ms
    • QUESTIONS, PRODUCT