• Cart
  • NOBODY BEATS OUR PRICES. GUARANTEED.Terms & Conditions

    Siemens 6/12 Circuit 60A 120/240V Generator Panel

    Model # EQG660D|Store SKU # 1000161601

    Overview
    Specifications
    Reviews

    Overview

    Model # EQG660D Store SKU # 1000161601

    3 Pole, 1 Phase 3 Wire, Made In Canada For Canada

    1. Suitable For Use With A Generator Having A Bonded Neutral Conductor
    1. Complete With Door
    1. Factory Ready For Use In Both Switched And Non-Switched Neutral Applications
    1. Additional Number Of Generator Circuits For More Flexibility
    1. Switch between LoadCentre or generator power source
    1. A complete line of accessories give Loadcentres the flexibility to meet application requirements

    Specifications

    Dimensions

    Assembled Depth (in inches)
    3.75
    Assembled Height (in inches)
    16.88
    Assembled Weight (in lbs)
    18.45
    Assembled Width (in inches)
    12
    Packaged Depth (in inches)
    4.5
    Packaged Height (in inches)
    19.5
    Packaged Weight (In lbs)
    18.95
    Packaged Width (in inches)
    13.75

    Details

    Certified
    Yes
    Country of Origin
    CA-Canada
    Maximum Amperage (Amps)
    60
    Number of Circuits
    12
    Voltage (volts)
    240

    Warranty / Certifications

    1 Year From Date Of Purchase With Proof Of Purchase, 1-888-302-5586
    6/12 Circuit 60A 120/240V Generator PanelPhoto of product3 Pole, 1 Phase 3 Wire, Made In Canada For Canada
    Siemens
    1000161601
    6/12 Circuit 60A 120/240V Generator Panel is rated 4.0 out of 5 by 3.
    • y_2019, m_10, d_17, h_21
    • bvseo_bulk, prod_bvrr, vn_bulk_2.0.13
    • cp_1, bvpage1
    • co_hasreviews, tv_0, tr_3
    • loc_en_CA, sid_1000161601, prod, sort_[SortEntry(order=SUBMISSION_TIME, direction=DESCENDING)]
    • clientName_homedepot-canada
    • bvseo_sdk, java_sdk, bvseo-4.0.0
    • CLOUD, getAggregateRating, 75ms
    • REVIEWS, PRODUCT
    Rated 3 out of 5 by from Difficult to balance generator load When powering 12 circuits it is very difficult to balance generator load. The panel splits the load as 8 breakers on one line and 4 breakers on the other. The line with 8 breakers is much easier to overload and cause the generator breaker to trip. This isn't a problem while operating from main power. Look at the accompanying picture. The upper and lower breakers are on one bus, and the middle breakers on the other.
    Date published: 2010-11-14
    Rated 5 out of 5 by from Great product This is a quality product. Saftey is the most important when it was designed. It is a great deal. Value and price
    Date published: 2007-03-05
    Rated 4 out of 5 by from did the job this worked well for my needs during power outages
    Date published: 2007-03-01
    • y_2019, m_10, d_17, h_21
    • bvseo_bulk, prod_bvrr, vn_bulk_2.0.13
    • cp_1, bvpage1
    • co_hasreviews, tv_0, tr_3
    • loc_en_CA, sid_1000161601, prod, sort_[SortEntry(order=SUBMISSION_TIME, direction=DESCENDING)]
    • clientName_homedepot-canada
    • bvseo_sdk, java_sdk, bvseo-4.0.0
    • CLOUD, getReviews, 29ms
    • REVIEWS, PRODUCT

    i need to download instruction manual for house generator panel

    it is a siemens generator panel installed in my basement to receive input from a Briggs and Stratton generator. I was not given a booklet with the generator panel and need to know the sequence of how to switch from usual electricity to input from the generator plugged into the side of the house.
    Asked by: Anonymous
    The order is 1. Switch off all breakers (below the linked breakers) in the transfer panel. 2. Switch the linked transfer breakers to the generator side. 3. Plug your generator into the plug on the side of the house. 4. Start your generator and let it warm up for 3-5 minutes. 5. Switch on the breakers (in the transfer panel) one at a time leaving 10 seconds before switching the next one on. This gives the generator a few seconds to get accustomed to the increased load. To switch back to commercial power reverse the order. 1. Switch off all breakers in the transfer panel. 2. Shutdown the generator. 3. Disconnect from the house. 4. Flip the linked breakers to utility power. 5. Switch the breakers on one at a time in the transfer panel. Again leaving a few seconds before switching the next on one.
    Answered by: Bulldog Dave
    Date published: 2019-07-18

    will Cutler Hammer breakers fit in the Seimens panel?

    Asked by: Anonymous
    Yes, the breakers will fit. However they are listed for use in CH panels, not Siemens and thus should not be used. You should install Siemens breakers.
    Answered by: Warren914
    Date published: 2013-10-23

    is there a safety between the main & generator breaker inEQG660D?

    Asked by: Anonymous
    Yes. There is a safety interlock to prevent both breakers from being on at the same time.
    Answered by: Warren914
    Date published: 2016-11-11

    can i change the 60amp breaker to a 20 or 30 amp breaker

    Asked by: Anonymous
    Yes, you can change the 60 amp breaker to a 20 or a 30 amp breaker as long as it is a Siemens plug in Q type breaker. I hope this helps.
    Answered by: OnlineAssociate
    Date published: 2013-10-23
    • y_2019, m_10, d_17, h_21CST
    • bvseo_bulk, prod_bvqa, vn_bulk_2.0.13
    • cp_1, bvpage1
    • co_hasquestionsanswers, tq_4
    • loc_en_CA, sid_1000161601, prod, sort_[SortEntry(order=LAST_APPROVED_ANSWER_SUBMISSION_TIME, direction=DESCENDING)]
    • clientName_homedepot-canada
    • bvseo_sdk, java_sdk, bvseo-4.0.0
    • CLOUD, getContent, 88ms
    • QUESTIONS, PRODUCT
    <?xml version="1.0" encoding="utf-8"?>