Durovent 22-inch x 4 ft. Rafter Vent (10-Pack)

Model # XUDV2248|Store SKU # 1000136854

Overview

Model # XUDV2248 Store SKU # 1000136854

For improved air circulation in the attic, install the Durovent 22-inch x 48-inch Rafter Vent (10-Pack). It can be cut to fit most joist spaces and is an affordable way to meet energy-code requirements for air flow. Use it between rafters to create an air channel through insulation to help keep air flowing freely in your attic.

  1. Improves insulation efficiencies, allows for cooler attics in the summer months, drier attics in the winter months and helps prevent ice-dam formation
  1. Install between rafters to provide an unobstructed air channel through insulation to keep air flowing from soffits to ridge vents
  1. For use in 24-inch or 16-inch rafter or truss applications
  1. Excellent option for new construction
  1. Can be cut to fit most joist spaces
  1. Cathedral ceilings require a continuous run of vents from intake to exhaust with a 1-inch space between each vent

Specifications

Dimensions

Assembled Depth (in inches)
48
Assembled Height (in inches)
2
Assembled Weight (in lbs)
0.15
Assembled Width (in inches)
22
Packaged Depth (in inches)
48
Packaged Height (in inches)
3
Packaged Weight (In lbs)
2
Packaged Width (in inches)
22

Details

Colour Family
Blue
Country of Origin
US-United States
Sound Barrier
No

Warranty / Certifications

www.adoproducts.com
22-inch x 4 ft. Rafter Vent (10-Pack)Durovent 22-inch x 4 ft. Rafter Vent (10-Pack)For improved air circulation in the attic, install the Durovent 22-inch x 48-inch Rafter Vent (10-Pack). It can be cut to fit most joist spaces and is an affordable way to meet energy-code requirements for air flow. Use it between rafters to create an air channel through insulation to help keep air flowing freely in your attic.
Durovent
1000136854
CAD24.36
The Home Depot Canada
22-inch x 4 ft. Rafter Vent (10-Pack) is rated 3.9 out of 5 by 127.
  • y_2021, m_9, d_20, h_20
  • bvseo_bulk, prod_bvrr, vn_bulk_3.0.19
  • cp_1, bvpage1
  • co_hasreviews, tv_10, tr_117
  • loc_en_CA, sid_1000136854, prod, sort_[SortEntry(order=SUBMISSION_TIME, direction=DESCENDING)]
  • clientName_homedepot-canada
  • bvseo_sdk, java_sdk, bvseo-4.0.0
  • CLOUD, getAggregateRating, 34ms
  • REVIEWS, PRODUCT
Rated 4 out of 5 by from Installed in my roof successfully... Installed in my roof successfully
Date published: 2021-08-27
Rated 5 out of 5 by from Easy to separate and easy to install... Easy to separate and easy to install
Date published: 2021-06-25
Rated 1 out of 5 by from Worst than terrible Toronto house. 10yrs old. This crap has melted, yes melted! Every baffle has melted closed at the soffit end. This stops all airflow. The attic becomes very hot. Need to replace every one. Don't know why they melt at the soffit end? A product designed to create airflow actually does the opposite!
Date published: 2021-06-16
Rated 4 out of 5 by from Easy to instal if you know the tricks People say it's to fragile and hard to work with. But that's just lack of understanding of how to install this stuff. A simple trick I use is to save old plastic milk jugs, cut them into 1 inch squares and staple through that into the durovent in the middle of the valley, and then staple a check at the top center of the valley. This holds it in place without tearing. Add a second durovent below the first overlapping an inch, staple a check in the middle of that piece and then staple a check where the two overlap. You don't need a hundred staples, you only need to add three staples max on each side. If you have a problem spot, staple a plastic check there. Use a 4 foot metal ruler to cut the durovent sections with a box cutter long ways facing down on somthing like plywood. Make cross cuts with sharp large scissors. When manuvering the panels into place grab the panels by the holes / divits, the holes are close enough together so that your hand can span two holes at once like a bolling ball, holding the panels this way prevents damage and makes it easier to position the panel. 3/8ths T50 staples are a good choice.
Date published: 2021-05-24
Rated 3 out of 5 by from Rating provided by a verified purchaser... Rating provided by a verified purchaser
Date published: 2021-05-04
Rated 4 out of 5 by from Easy to install and a perfect fit. They can be... Easy to install and a perfect fit. They can be split for two different widths of rafters. Insulation went over them, but there is no way to tell yet if they are effective like they say. It makes sense since there are two channels for the air to travel and take the moisture out. Let’s hope they do what they say they will!
Date published: 2021-05-03
Rated 5 out of 5 by from Easy to install. No need to pay anyone. DIY for... Easy to install. No need to pay anyone. DIY for dummies.
Date published: 2021-04-21
Rated 5 out of 5 by from Easy to use and manage. Good price. Easy to use and manage. Good price.
Date published: 2021-04-21
  • y_2021, m_9, d_20, h_20
  • bvseo_bulk, prod_bvrr, vn_bulk_3.0.19
  • cp_1, bvpage1
  • co_hasreviews, tv_10, tr_117
  • loc_en_CA, sid_1000136854, prod, sort_[SortEntry(order=SUBMISSION_TIME, direction=DESCENDING)]
  • clientName_homedepot-canada
  • bvseo_sdk, java_sdk, bvseo-4.0.0
  • CLOUD, getReviews, 38ms
  • REVIEWS, PRODUCT

what are they made of ?

what are they made of ?
Asked by: gf
Styrofoam - very thin, but that's all you need
Answered by: KYLE
Date published: 2020-12-14

which is best way to install this product

which is best way to install this product
Asked by: radar
The Durovent website has detail on installation. It is installed from the sofit up the underside of the roof to allow air to flow past the insulation.
Answered by: pofinmt
Date published: 2020-09-08

Do the Windblock peices come with the baffles?

Asked by: Hugothor
No. I would consult Home Depot for these. You may have to order them.
Answered by: pofinmt
Date published: 2020-09-08

Can I install Durovent from soffit to peak and then encapsulate my attic with foam?

Can I install Durovent from soffit to peak and then encapsulate my attic with foam?
Asked by: Brian
This product is designed to allow air flow from the soft up past the insulation. If your insulation is higher than one piece, overlap another piece a bit and staple it in. Keep in mind this is about air flow.
Answered by: pofinmt
Date published: 2020-09-08

What is the NFVA rating of these vents?

What is the NFVA rating of these vents?
Asked by: PJ
Hi, I am not sure what that rating is, please call 866-240-4933 and select retail.
Answered by: ADO Product Expert
Date published: 2020-08-31

How do you trim / adjust these 22 in. to fit in a standard 14 in. cavity (roof rafters on 16 in. ...

How do you trim / adjust these 22 in. to fit in a standard 14 in. cavity (roof rafters on 16 in. center)?
Asked by: dcotter
Buy ones for 16" on center
Answered by: Valas
Date published: 2020-07-14

Getting ready to do some blow in inulation inthe attic... do these go between EVERY roof truss ?? Or just above the soffet vents ???

Asked by: Bryan
Yes every truss space gets one.
Answered by: Valas
Date published: 2020-07-27

How do you install this on an existing roof (that has millions of nails protruding down)??

How do you install this on an existing roof (that has millions of nails protruding down)??
Asked by: Jennifer
Very carefully. if there are tons of protruding nails use them. Once you have them pushed onto nails throw in a couple staples and insulate. Insulation will hold it up.
Answered by: Valas
Date published: 2021-01-13
  • y_2021, m_9, d_20, h_20CST
  • bvseo_bulk, prod_bvqa, vn_bulk_3.0.19
  • cp_1, bvpage1
  • co_hasquestionsanswers, tq_14
  • loc_en_CA, sid_1000136854, prod, sort_[SortEntry(order=LAST_APPROVED_ANSWER_SUBMISSION_TIME, direction=DESCENDING)]
  • clientName_homedepot-canada
  • bvseo_sdk, java_sdk, bvseo-4.0.0
  • CLOUD, getContent, 216ms
  • QUESTIONS, PRODUCT