Model # CHOM120CAFI Store SKU # 1001795064

Beginning in 2015, the Canadian Electrical code will require the use of Combination Arc Fault Circuit Interrupters (CAFCIs) in each branch circuit in the home suppling 125V receptacles rated 20A or less (except in the kitchen/bathrooms and sump pump). The CAFCI breaker effectively stops the flow of current before an electrical fire from dangerous arcing can start. Typical causes of dangerous arc faults in a residence are: cord insulation damage from furniture, drywall screw piercing insulation, punctured cable by nail or staple. A standard feature in all HomeLine CAFCI circuit breakers is the TIME SAVER diagnostics test that assists in identifying the type of fault that last occurred in a circuit. It saves money by reducing troubleshooting time, simple to use and requires no tools.

  1. Detects unintended arc faults, overloads and short circuits
  1. White push to test button
  1. Uses pigtail neutral for installation
  1. Compatible only with Canadian HomeLine loadcentres
  1. Built in TIME SAVER diagnostics feature
  1. 10,000 AIR

Specifications

Dimensions

Assembled Depth (in inches)
3.0
Assembled Height (in inches)
4.75
Assembled Weight (in lbs)
0.576
Assembled Width (in inches)
1.0
Packaged Depth (in inches)
3
Packaged Height (in inches)
4.75
Packaged Weight (In lbs)
0.576
Packaged Width (in inches)
1

Details

Amperage (amps)
20 Amp
Breaker Type
Single Pole
Certifications and Listings
CSA Certified
Interruption Type
CAFCI
Mounting Type
Pig Tail
Package Quantity
1
Power Distribution Features
Arc Fault Interrupter
Voltage (volts)
120 volts

Warranty / Certifications

Lifetime warranty
Homeline Single pole 20 Amp Combination Arc Fault (CAFI) Pigtail Circuit BreakerSchneider Electric Homeline Single pole 20 Amp Combination Arc Fault (CAFI) Pigtail Circuit BreakerBeginning in 2015, the Canadian Electrical code will require the use of Combination Arc Fault Circuit Interrupters (CAFCIs) in each branch circuit in the home suppling 125V receptacles rated 20A or less (except in the kitchen/bathrooms and sump pump). The CAFCI breaker effectively stops the flow of current before an electrical fire from dangerous arcing can start. Typical causes of dangerous arc faults in a residence are: cord insulation damage from furniture, drywall screw piercing insulation, punctured cable by nail or staple. A standard feature in all HomeLine CAFCI circuit breakers is the TIME SAVER diagnostics test that assists in identifying the type of fault that last occurred in a circuit. It saves money by reducing troubleshooting time, simple to use and requires no tools.