Get Father’s Day gifts with free delivery.  Shop Event

Overview

Model # CHOM3060M200GC Store SKU # 1001817792

Homeline load centers offer features HOM breakers, ground fault circuit breakers and arc fault interrupters. CHOM Load Centers enable the use of a full complement of accessories. Systems are single phase and are rated for indoor use or are rain proof. CHOM load centers are designed for residential and industrial use to protect electrical systems, equipment and people. This CHOM Load Center has a plug on neutral main circuit breaker that is rated at 200 A single phase. This CHOM load center provides a 22 kA breaking capacity. This system provides 30 spaces in a NEMA 1 enclosure.

  1. The electrical connections are lugs.
  1. A grounding bar is included but not installed.
  1. The box lugs will accept a wire range of 4 AWG to 250 kcmil copper or aluminum wire.
  1. This load center has a height of 33.78 inches, a width of 14.25 inches and depth of 3.75 inches.
  1. The combination flush surface cover is painted white.
  1. CSA certified.
  1. Seamlessly supports EV chargers, heat pumps, and solar-ready home upgrades for future-proof power

Specifications

Dimensions

Assembled Depth (in inches)
3.75
Assembled Height (in inches)
33.78
Assembled Weight (in lbs)
31.62
Assembled Width (in inches)
14.25
Packaged Depth (in inches)
3.75
Packaged Height (in inches)
33.78
Packaged Weight (In lbs)
31.62
Packaged Width (in inches)
14.25

Details

Certifications and Listings
CSA Certified
Individual/Kit
Load Center and Breaker Kit
Indoor/Outdoor
Indoor
Maximum Amperage (Amps)
200 Amp
Mounting Type
Plug-On Neutral
Number of Circuits
60 Circuit
Number of Phases
1
Number of Spaces
30 Spaces
Panel Type
Main Breaker Panels
Voltage (volts)
120/240 volts

Warranty / Certifications

Lifetime Warranty
Homeline 200 Amp Main Breaker Load center 30 Spaces 60 Circuits MaximumSchneider Electric Homeline 200 Amp Main Breaker Load center 30 Spaces 60 Circuits MaximumHomeline load centers offer features HOM breakers, ground fault circuit breakers and arc fault interrupters. CHOM Load Centers enable the use of a full complement of accessories. Systems are single phase and are rated for indoor use or are rain proof. CHOM load centers are designed for residential and industrial use to protect electrical systems, equipment and people. This CHOM Load Center has a plug on neutral main circuit breaker that is rated at 200 A single phase. This CHOM load center provides a 22 kA breaking capacity. This system provides 30 spaces in a NEMA 1 enclosure.